0-20ppb DO probe/sensor/electrode
Home> Sell >0-20ppb DO probe/sensor/electrode

0-20ppb DO probe/sensor/electrode

Item No.: 264643
OverviewQuick DetailsPlace of Origin:Shanghai, China (Mainland)Brand Name:BOQUModel Number:DOG-208FAElectrode response time::about 60 second
INQUIRY
Description
Overview
Quick Details
Place of Origin:
Shanghai, China (Mainland)
Brand Name:
BOQU
Model Number:
DOG-208FA
Electrode response time::
about 60 seconds
Product name:
DO Probe
Diameter:
12*120mm
Material:
316L Stainless Steel
Application:
Bioreactor / fermentor
 
Product Description

 

 

 

DOG-208FA High Temperature fermentation

Dissolved Oxygen Electrode

 

 

0-20ppb DO probe/sensor/electrode


DOG-208FA DO electrode, which is specially designed to be resistant to 130 degrees steam sterilization, the pressure auto-balance oxygen electrode, for liquids or gases dissolved oxygen measurement, the electrode is most suitable for small microbial culture reactor dissolved oxygen levels on line. Also can be used for environmental monitoring, wastewater treatment and aquaculture in-line measurement of dissolved oxygen levels. Size Φ12, Φ19 and Φ25 type for option.

 

0-20ppb DO probe/sensor/electrode
 

 

 

Dissolved oxygen electrode characteristics:

 

1.DOG-208FA Industrial High Temperature fermentation Dissolved Oxygen Electrode,using polarographic          oxygen electrode principle.

 2.With imported breathable membrane heads.

 3.Steel gauze electrode membrane and silicone rubber

 4.Endure high temperature, deformation characteristics

 

 

Technical parameters:

 

Electrode body material: stainless steel

Permeable membrane: fluorine plastic,silicone,stainless steel wire mesh composite membrane.

Cathode: diameter 0.5 mm platinum wire

Anode: diameter 0.3 mm silver

Electrodes built-in temperature sensor: 22 kilohms negative temperature coefficient thermistor semiconductor (under room temperature)

Internal electrolyte: chloride solution

The response current in the air: 60 Na Ampere.

The response current in a nitrogen atmosphere: less than one percent response current of response in air.

 Electrode response time: about 60 seconds (up 95% response)

 Electrode Response Stability: a constant oxygen partial pressure at a constant temperature environment,

 Response current drift: less than 3% per week

 Liquid mixing flow to the electrode response: 3% or less (in water at room temperature)

 Electrode Response Temperature Coefficient: 3% (at room temperature)

 Insert the electrode diameter: 12 mm, 19 mm, 25 mm optional

 Electrode insertion part length: 80,150,200,250,300 mm optional

 

 

                                  0-20ppb DO probe/sensor/electrode

 

                                  0-20ppb DO probe/sensor/electrode

 

 

 

 

                                                           

 

 

 

 

 

 

 

 

                                                

                     

 

 

 

 

 

 

0-20ppb DO probe/sensor/electrode

 

0-20ppb DO probe/sensor/electrode

 

0-20ppb DO probe/sensor/electrode

 

0-20ppb DO probe/sensor/electrode

 

0-20ppb DO probe/sensor/electrode

 

0-20ppb DO probe/sensor/electrode

 

 

 

Certifications

                          

 0-20ppb DO probe/sensor/electrode

 

 

0-20ppb DO probe/sensor/electrode