DDG-208 Industrial online Conductivity Analyzer
With strong environmental adaptability, clear display, easy operation and excellent measuring performance, the DDG-208 Intelligent On-line Conductivity Meter has very high performance-price ratio. It can be widely used for continuous monitoring of the conductivity values of the solutions used in the following industries: thermal power plants, chemical industry, chemical fertilizer, metallurgy, environmental protection, pharmacy manufacturing, biochemistry, foodstuff and running water.
Features
Fully intelligent: It adopts high-precision AD conversion and single chip microcomputer processing technologies |
and can be used for conductivity and temperature measurement, automatic temperature compensation, automatic |
range switching, self-checking, etc. |
Multi-parameter display: The conductivity and temperature values can be displayed on the same screen at the |
same time. It adopts LED display module with high brightness. the displayed values can be seen from |
along distance away. |
Strong interference immunity: Its current output adopts optoelectronic isolating technology. This meter has |
stronginterference immunity and the capacity of long-distance transmissionas well as excellent electromagnetic |
compatibility. |
25℃ Conversion: The conductivity value measured at the current temperature is converted to that at 25℃; |
thus, this conductivity meter always displays the conductivity value at 25℃. Therefore, this meter is especially |
suitable for testing the various water solutions in power plants. |
Technical Indexes
1. Standard: JB/T6855-93 "Industrial Conductivity Meter" |
2. Conductivity measuring range: 0.01~20µS/cm(Electrode: K=0.01) |
0.1~200µS/ cm (Electrode: K=0.1) |
1.0~2000µS/ cm (Electrode: K=1.0) |
10~20000µS/ cm (Electrode: K=10.0) |
3. Accuracy: conductivity: ±1.0%FS; temperature: ±0.5℃ |
4. Intrinsic error of electronic units: conductivity: ±0.5%F.S, temperature: ±0 3℃(0~60℃) |
5. Range for automatic temperature compensation: 0~80℃, with 25℃ as the reference temperature |
6. Water sample tested: 0~80℃, 0.6Mpa |
7. Intrinsic error of the instrument: conductivity: ±1.0%F.S, temperature: ±0.5℃(0~60℃) |
8. Automatic temperature compensation error of the electronic unit: ±0.5%FS |
9. Repeatability error of the electronic units: ±0.2%FS±1 unit |
10. Stability of the electronic unit: ±0.2%±l unit FS/24H |
11. Alarm error of the electronic unit: ≤±3.0%FS |
12. Error of electronic unit caused by ambient temperature: ≤±0.5%FS |
13. Error of the electronic unit caused by the supply voltage: ≤±0.3%FS |
14. Isolated current output: 4~20mA (load<750kΩ) |
15. Output current error of the electronic units: ≤±l.0%FS |
16. Alarm relay: AC220V, 3A |
17. Communication interface: RS485(optional) |
18. Power supply: AC 220V±22V, 50Hz±1Hz, DC24V(optional) |
19. Protection grade: IP65 |
20. Overall dimension: 146 (length) x 146 (width) x 108 (depth) mm; dimension of the hole: 138 x 138mm |
21. Weight: 0.6kg |
22. Working conditions: ambient temperature: 0~60℃; relative humidity <85% |
23. The connection tubes for inlet and outlet water: Hard pipe or soft pipe. |